M3 Software ChangeLog


M3 v4.10.12					3/3/2023


Fixed:

-Fixed potential crash when opening part programs with large Profiles.
-Fixed refresh issue that caused tolerance results to not display upon initial report template selection.
-Fixed playback of created features in Imperial units.
-Fixed High accuracy mode playback of auto-programmed (DXF) features.
-Fixed import of DXF entities defined with a negative extrusion direction.
-Added support for the Near/Far probe in the Step and Repeat function.
-The number of segments to draw for Arcs and Circles in the Part View and Overlay are now consistent.  Default value increased to 64 (from 32).

[PartView]
NumCircleSegments=64



M3 v4.10.10					9/21/2022


Added:

-Added support for the measurement of Blob features that extend outside of the Field of View on a manual measuring system. The "Auto Enter" countdown timer should be used to initiate the addition of blob points as you move beyond the initial Field of View.
-Added support for defining a start and end point for blob point collection. The workflow utilizes point features as the start and end points. Press "Measure Blob", select the start and end point "point" features from the feature list, and press "Enter". This is supported in both manual and CNC systems.
-Improved the drawing speed of high density dataclouds, such as blob features, when displayed in Live Video.
-Added a new Factory Option called "Field of View Mode". This new option can be used in place of the metlogix.ini parameter "FOVPlayback" for enabling Field of View playback mode for non-encoded systems.
-Added support for a "Crosshair Only" configuration in the M3 software. The "Crosshair Only" factory option should be enabled to utilize this mode.
-Added the ability to utilize more than one Photonics F3000 USB/Serial light control modules simultaneously.
-Added the "jpeg" image format to the available export options for Full Frame Image Archiving. 
-Added a new metlogix.ini parameter for modifying the size of Full Frame Archive images exported from M3.

[Video]
ArchiveScale=100

-Added the ability to change the TCP port number for the "Remote Control" module, in the event of conflicts.

[Remote]
RemoteControlPortNumber=3000

Fixed:

-Fixed the target destination and target filename functions for PDF export from the custom export dialog.
-Fixed the "Rotate Skew" function. Coordinate system rotation now executes according to the entered angular value. 
-Fixed an issue with the playback of programs containing both a stitch and print/archive image steps. 
-Fixed an update issue with the feature detail view of individually selected best/worst profile whiskers, after program playback.
-Fixed angular issue with playback of created features.



M3 v4.10.00					7/19/2022


Added:

-Added support for the IDS Peak SDK camera interface.
-Added support for Variable usage within the Create Feature form.
-Added prompt for setting a default variable value, when adding a variable via the User Message step.
-Added new Gage Circle construction from (1) line and (1) arc feature.
-Added support for Profile Fit of Touch Probe measurements against imported candidate profiles.
-Added a new setting to Probe Rack settings screen called "Approach Offset". The entered offset will set the distance away from the probe rack bay that the touch probe will stop at, prior to parking or retrieving a probe.
-Added validation check for ACF file during NLEC calibration import. Candidate ACF file will now be checked against the current import feature list to ensure that row and column count and spacing match.
-Improved the display of the Indexable Probe Dialog on low resolution displays (1366x768).
-Significantly improved the export speed of data to Microsoft Excel.
-Added support for Explode Points to the main UI. Enable the Explode Points button in Desktop Settings. Once enabled the Explode button will be located in the Measure Point submenu.
-Points exploded from features now inherit the projection from their parent feature.
-Touch Probe points are now inhibited while in the Probe Selection dialog.
-Added support for the Add Points CNC routine for boss Cone features.
-Added support for the Teledyne DALSA X-ray detector.
-Added pixel correction to the DXF Overlay based on FOV calibration data.

[Video]
CorrectDxfPixels=1


Fixed:

-Fixed a case within Auto Programming for datum features that are larger than the FOV. Target VED Probe position is now correct.
-Fixed the incorrect display of the Probe Rack Swap warning message in normal CNC playback.
-Fixed the display of the Stitch Mode buttons while in Advanced Recording Mode.
-Fixed the display of Live Video Overlay Annotation when printed from program playback.
-Fixed the Print of the Live Video image, when it immediately follow a Part View printout in playback.
-Fixed the “Stop on Tol Fail” function for Calc features.
-Fixed the calculation of the “Amount Over” value for features toleranced in ++/-- mode.
-Fix for the Park Position on Shutdown. Machine coordinates are now used regardless of currently selected probe.
-Fixed the display of Run Date and Run Time in the Report Templates.
-Fixed a crash that could occur during the FOV calibration routine when targets are very near the edge of the field of view.
-Fixed the Exit and Keyboard buttons in the main User Login screen.
-Fixed a case where switching report templates could cause the report contents to be scrolled out of view.
-Fixed the "Select Similar" functionality in the Report View, while editing cell contents.
-Fixed the setting of Nominal Angle values within the Calc feature type.
-Fixed the Best Form calculation for Plane Features in the YZ and ZX planes.
-Fixed a rare case where profile points could be fit to a portion of a profile, not closest to the nominal.
-Fixed the feature display in the part view after program playback. Features are now displayed in part coordinates in the part view.
-Fixed a case where a circle construction from a YZ or ZX cylinder or cone could be projected in XY.



M3 v4.00.20					3/3/2022


Added:

-Added new camera interface to support the TSI line of machine vision cameras. 
-Added new 64bit interface for the Imaging Source camera type.
-Added support for goto steps in the step and repeat function.
-Added support for passing edge teach parameters to the pattern recognition mechanism.
-Added the ability to construct pattern features from probed features. Patterns generated in this way will function in the same way as "marquee-taught" patterns.  
-Expanded the Thread Measurement function to support flat peaked threads such as those found on "No-Go" thread plugs.
-Added new MTI CSV Export function. 
-Added support for the "Feature Properties" function in edit mode.
-Added (4) new system variables for querying the current XYZ or Q encoder position. [MlxX],[MlxY],[MlxZ],[MlxQ].
-A new setting has been added to the Probe Rack Settings screen called "Park probe on switch to VED". This setting is set to Yes by default. When set to No the system will not park the currently held touch probe in the probe rack, when switching from Touch Probe to VED.
-Added support for the OE MTDV Stepper Controller for use with OE Lens Systems.
-Added new metlogix.ini parameter to set the digital zoom type to "ZoomFill" at M3 startup.

[Startup]
ZoomFill=1


Fixed:

-Fixed a case where construction of profile features from more than two probed parent features was not functioning.
-Fixed a crash that could occur in the TCPIP Remote Control module. New synch code was added to deal with command exchange delays in host/server interface.
-Fixed the use of cylinder features as reference features for parallelism and perpendicularity tolerances.  
-Fixed a rare case where profile fit results from alternate point sources was incorrectly executed. This could occur when multiple feature sources were used.
-Fixed the display of custom template names when printed in the report header. 
-Fixed a duplicate display of the UCS custom template item when using the template editor.
-Fixed various cases of missing tooltip text.
-Fixed overflow of annotation text on live video when using an enlarged font size.
-Fixed a case where circle features changed to arc features caused a failure in program playback. 
-Fixed the Windows dialog button call for the Export File function.
-Fixed Z axis CNC playback for features measured with the Optical Edge probe. 
-Fixed the formatting in the Cloud CSV export file for profile features. 
-Fixed case where the target radius and arrow were not updated properly for features played back in Assist Mode. 
-Fixed missing Image Stitch functionality while using Advanced Recording Mode.
-Fixed minor UI issues in the new Program Properties dialog (Basic/Advanced).
-Fixed the display color of multiple tolerance result combinations when using the Live Video Overlay in programs configured for "Multiple parts in the FOV" mode.
-Fixed a case where the FOV calibration routine would fail, and added a perimeter warning visual guide.



M3 v4.00.10					10/27/2021


Added:

-Added a new RS232 Send key mapping mechanism for the function keys (F keys) on a keyboard. These are configured via the following metlogix.ini parameter. The list below represents the defaults.

[ShortCuts]
F1=
F2=
F3=R
F4=
F5=X
F6=Y
F7=Z
F8=XY
F9=L
F10=D
F11=A
F12=XYZLDA

-Added support for the OpEng TCZR Zoom Turret device.
-Added support for the NMI Turret/Light interface. 
-Modified the Program Properties dialog to allow space for additional items. The dialog is now separated into 2 "pages", Basic and Advanced. The pages can be toggled using a new button in the top right corner of the program properties dialog.
-Added a new program playback mechanism called "High Accuracy Mode". This new mode executes VED probing steps at the middle of the field of view, regardless of where they were recorded. High accuracy mode is enabled in the "Advanced" page of the program properties dialog.

Fixed:

-Restored the Goto dialog behavior where the Absolute/Relative goto type is "remembered". The values entered for a relative goto are now restored when a subsequent goto is invoked.
-Resolved an issue where small amounts of video overlay misalignment could occur in the display of probed points, at specific digitally zoomed positions.
-Fixed the Light Control Slider Interface channel mapping for cases where specific sliders (Top/Bottom/Misc.) are not enabled, and the Quadrant interface is being used.
-Fixed the JP2 Image Load function.
-Restored both the Round and Square FOV indicators for M3 Optical Edge configurations. 
-Small fixes for use of the Alt key functionality with German Language keyboards.
-Fixed cases where changing the file extension in the Windows Open File dialogs did not automatically update window contents.
-Fixed a missing 3D features button when using the metlogix.ini parameter "ShowAll3DButtons" to display the 3d feature measurement buttons in the upper-level measure toolbar.
-Fixed the storage and retrieval of Thread Annotation(markup) in part programs.




M3 v4.00.00					8/11/2021	


V4 Feature Set:
-each feature below is further described in the M3 V4 User Guides.


Migrated the M3 to a 64bit application
Direct PDF Export of Measuring Results
Export to Live Excel Sheets w/ Incremental Programmatic Export and Improved Speed
Additional Custom Text Fields for Reporting
3D Line Support via New "Axis Feature"
3D Distance Constructions with Changetypes
Update to Positional Registration via New Registration Datum Feature
Save/Load Reference Frame File Mechanism 
Pallet Program reference frame, via loaded ref frame file.
Program Linking
Global Variables Mechanism
Variables in Goto Steps and Calc Steps
Advanced Recording and Edit Program Path Mechanism
Copy/Cut/Paste Program Steps
Nearest/Farthest VED Probe
Edit VED Probe Steps Mechanism
Color and Contrast Image Processing Functions
Profile Fitting using Optical Edge Detection (Optical Comparators)
Profile Fitting from Measured Features
Profile Fitting from Previously Fit Profiles


Also Added:

-Introduced new Version 4 Settings file. Existing Settings files are left intact upon update.
-Added a new M3 software installation utility.	
-Added new graphical display of hidden rows in the report view. A magenta line will now be displayed where report rows have been hidden.
-Added the ability to edit report templates while a program is loaded. 
-Added the ability to Save Part programs in modes other than Edit mode.
-Changed the default color of M3 dialogs.
-Added new field type to the report template editor for display of the amount of "Bonus" from a True Position tolerance.
-Changed the layout of the program playback control buttons. A Play, Edit, and Rec button will now be displayed at the top of the program list in playback.
-Improved Auto Programming speed for large part program.
-Added new program playback graphics to aid in VED playback diagnostics. The new setting is called "Show debug fire stitches" and can be found in Program Settings.
-Improved Excel cell formatting issues when exporting data directly to Excel.
-Improved playback optimization for features probed using the Multi-Measure (wand) function. Features are now played back at the single FOV in which they were probed.
-Improved the speed of keyboard text entry into User Message Dialog text entry fields. 
-Changed ShapeCalibration resolution to support one digit more than the currently configured display resolution. 
-Added new "Import" button to the Profile measurement toolbar, used for loading candidate profiles to the feature list for Profile Fit operations. 
-Added new Single Step mode for measurement substeps. When single stepping through expanding program steps, each probe move will be executed individually. Long press a program feature step to expand it.
-Added new Edit Probe Point and Edit Goto dialog to Edit mode. Long press any Goto step or Touch Probe substep to display the new Edit dialog in the upper left viewport. Edit either the Absolute position, or use the Relative mode to increment an existing position by the specified amount.
-Implemented new Probe Path mechanism, enabled with the show/hide path button. Goto's and Touch Probe Points are now displayed as "edit-able" nodes in the part view path graphics.
-Added new "Highlighting" mechanism to the program list to better show light control step/feature step relationship.
-Added a new "Stop playback on tolerance failure" mode. This setting is part specific and configured in the Program Properties step. When enabled playback will stop on a program step resulting in a failed tolerance. The operator can continue, remeasure, or Quit the program.
-Added the ability to perform Step and Repeat on Image Archive program steps.
-Added the ability to apply tolerances to profile fits performed using only the nominal profile.
-Added support for recording B Axis Goto Rotary moves in program edit mode.
-Changed the DemoStage default bitmap mechanism to be "rolling". THis allows for use of more than one sample demo part in emulated programs. 
-Added support for Windows Task Switching to M3 while it is minimized. 
-Added support for the new Unified Correction File import and Export. Stage Error Correction data can now be exported to, or imported from a UCF_SN.tsv file in the Metlogix/Settings directory. The Export UCF and Import UCF buttons can be found in the Error Correction settings screen. 
-Added new option to mlxlog.exe called Time (On/Off). When set to On, a date and time stamp will be added to each log line. 
-Added support for the Metlogix LED Control Card.
-Added new program playback timer, and program feature counter to playback, displayed in the program status toolbar. Enable with the following metlogix.ini parameter;

[Programming]
ShowCurRunStep=1 


Fixed:

-Fixed an issue with Goto positions in cases where Dual Layer NLEC and Z axis SLEC are being applied.
-Fixed a column/row offset problem with the "Direct to Excel" function.